Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Arq. bras. neurocir ; 40(3): 207-209, 15/09/2021.
Article in English | LILACS | ID: biblio-1362098

ABSTRACT

Objective Terson syndrome (TS), also known as vitreous hemorrhage, is reported in patients with subarachnoid hemorrhage caused by a ruptured aneurysm. This study aims to evaluate the presence of ocular hemorrhage in such patients, trying to identify those who could benefit from the specific treatment for visual deficit recovery. Methods Prospective study of 53 patients with spontaneous subarachnoid hemorrhage (SSAH) due to ruptured aneurysm. The patients were evaluated for vitreous hemorrhage through indirect fundoscopy with 6 to 12 months of follow-up. Results The ages of the patients ranged from 17 to 79 years-old (mean age, 45.9 11.7); 39 patients were female (73%) and 14 were male (27%). Six patients (11%) presented TS, and 83.3% had a transient loss of consciousness during ictus. Conclusions An ophthalmologic evaluation must be routinely performed in subarachnoid hemorrhage patients, especially in those with worse neurological grade. Moreover, prognosis was bad in TS patients.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aortic Rupture/complications , Subarachnoid Hemorrhage/etiology , Vitreous Hemorrhage/mortality , Vitreous Hemorrhage/diagnostic imaging , Aortic Rupture/mortality , Aortic Rupture/diagnostic imaging , Prognosis , Subarachnoid Hemorrhage/mortality , Subarachnoid Hemorrhage/diagnostic imaging , Chi-Square Distribution , Data Interpretation, Statistical , Diagnostic Techniques, Ophthalmological
2.
Rev. bras. cir. cardiovasc ; 31(2): 115-119, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-792655

ABSTRACT

Abstract Introduction: Optimal surgical management for acute type A aortic dissection (AAAD) remains unclear. The in-hospital mortality rate is still high (15%), and the intraoperative bleeding is an independent risk factor for hospital mortality. Objective: The aim of our study was describe a new method for aortic anastomosis in the repair of AAAD and report the hospital mortality and bleeding complications. Methods: Between January 2008 and November 2014, 24 patients, 16 male, median age 62 years, underwent surgical treatment of AAAD. The surgical technique consisted of intussusception of a Dacron tube in the dissected aorta, which is anastomosed with a first line of 2-0 polyester everting mattress suture and a second line of 3-0 polypropylene running suture placed at the outermost side. Open distal anastomosis was performed with bilateral selective antegrade cerebral perfusion in 13 (54.1%) patients. Results: Cardiopulmonary bypass and aortic clamping time ranged from 75 to 135 min (mean=85 min) and 60 to 100 min (mean=67 min), respectively. The systemic circulatory arrest ranged from 29 to 60 min (mean=44.5 min). One (4.1%) patient required reoperation for bleeding, due to the use of preoperative clopidogrel. The postoperative bleeding was 382-1270 ml (mean=654 ml). We used an average of 4.2 units of red blood cells/patient. There were two (8.3%) hospital deaths, one due to intraoperative bleeding and another due to mesenteric ischemia. The average length of stay in the intensive care unit and hospital was 44 hours and 6.7 days, respectively. Conclusion: This new method for surgical correction of AAAD was reproducible and resulted in satisfactory clinical outcomes.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Aortic Aneurysm/surgery , Postoperative Hemorrhage/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/statistics & numerical data , Aortic Dissection/surgery , Aorta/transplantation , Aortic Aneurysm/mortality , Sweden , Brazil , Treatment Outcome , Hospital Mortality , Polyethylene Terephthalates/therapeutic use , Postoperative Hemorrhage/mortality , Blood Vessel Prosthesis Implantation/mortality , Perioperative Period/statistics & numerical data , Preliminary Data , Aortic Dissection/mortality
3.
J. bras. neurocir ; 21(4): 215-219, 2010.
Article in Portuguese | LILACS | ID: lil-588328

ABSTRACT

Objetivos: A estimulação da medula espinhal (EME) tem sido considerada eficaz no tratamento da dor neuropática crônica. O presente estudo tem como objetivo avaliar os resultados em longo prazo da EME, em pacientes portadores de ciatalgia neuropática crônica, considerando suas indicações, os mecanismos de ação e as complicações. Casuística: Foram estudados 308 pacientes portadores de ciatalgia neuropática crônica rebelde ao tratamento clínico submetidos à EME, no Serviço de Neurocirurgia do Centro Hospitalar Regionale Universitário de Lille, França, no período de 16 anos. O tempo médio de seguimento foi de 7,8 anos. Resultados: A maioria dos pacientes (95%) apresentou um alívio da dor ciática. Em 49% o resultado foi considerado excelente (alívio completo da dor), em 28% bom (alívio superior a 70%), em18,4% moderado (alívio entre 25% e 70%) e ruim em 4,6%(sem melhora da dor), de acordo com escala visual analógica.Não foram observadas complicações graves. Conclusão :Conclui-se que a EME é um método útil no tratamento da ciatalgia crônica de origem neuropática, com bons resultados a longo prazo, em pacientes resistentes a outras modalidades terapêuticas. Trata-se de terapia não-destrutiva, ajustável e reversível.


Subject(s)
Humans , Pain , Spinal Cord
4.
Rev. bras. cir. cardiovasc ; 24(2): 194-199, abr.-jun. 2009. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-525551

ABSTRACT

OBJETIVO: Avaliar a evolução de pacientes de alto risco submetidos a aortoplastia redutora com contenção externa associada a troca valvar aórtica. MÉTODOS: Seis pacientes portadores de aneurisma de aorta ascendente e valvopatia aórtica, sendo quatro do sexo masculino, foram incluídos no estudo. Um paciente apresentava insuficiência mitral importante. A idade variou de 61 a 70 anos (média de 65,7 anos). A insuficiência aórtica foi a indicação de troca valvar em 83,3 por cento dos pacientes e a estenose aórtica, em 16,7 por cento. Os critérios de inclusão foram: pacientes portadores de valvopatia aórtica com indicação cirúrgica, aorta ascendente com diâmetro > 5,5 cm, EuroSCORE > 6 e idade acima de 60 anos. O diâmetro da aorta ascendente variou de 57 a 68 mm (média de 63,7 mm). Análise estatística foi realizada utilizando o teste t pareado para as variáveis estudadas, com nível de significância menor que 5 por cento. RESULTADOS: Todos os pacientes foram submetidos a aortoplastia redutora com contenção externa associada a troca valvar aórtica. Não houve mortalidade hospitalar na série estudada. Um (16,7 por cento) paciente apresentou fibrilação atrial no pós-operatório. O diâmetro médio da aorta ascendente foi de 37,0 +4,5 mm aos 6 meses de pós-operatório (P < 0,0001, em relação ao pré-operatório). A curva atuarial de sobrevivência é de 100 por cento ao final de 28 meses de seguimento. CONCLUSÃO: A aortoplastia redutora associada a contenção externa e troca valvar aórtica é uma opção terapêutica com resultados promissores a médio prazo, em pacientes de alto risco cirúrgico portadores de aneurisma de aorta ascendente e valvopatia aórtica.


OBJECTIVE: To assess the midterm follow-up of reduction aortoplasty with external wrapping associated with aortic valve replacement in high risk patients. METHODS: Six patients with ascending aortic aneurysm and aortic valve disease were included in this study. Four of them were male. The age ranged from 61 to 70 years (mean 65.7 years). One patient presented severe mitral valve insufficiency. All patients underwent aortic valve replacement (83.3 percent with aortic insufficiency and 16.7 percent with aortic stenosis). The inclusion criteria were: surgical aortic valve disease, ascending aortic aneurysm > 5.5 cm, EuroSCORE > 6 and age above 60 years. The ascending aortic diameter ranged from 57 to 68 mm (mean 63.7 mm). Data were analyzed by paired T test for comparison between the studied variables and P < 0.05 was considered significant. RESULTS: All patients underwent reduction aortoplasty with external wrapping associated with aortic valve replacement. The postoperative hospital mortality and morbidity was 0 percent and 16.7 percent (atrial fibrillation), respectively. The mean ascending aortic diameter was 37.0 + 4.5mm after 6 months of follow-up (P < 0.0001, compared with the preoperative period). The actuarial survival curve after 28 months of follow-up was 100 percent. CONCLUSION: Reduction ascending aortoplasty with external wrapping associated with aortic valve replacement is a safe procedure with excellent midterm results in high risk patients with ascending aortic aneurysm and aortic valve disease.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Aorta/surgery , Aortic Aneurysm/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Aorta/pathology , Epidemiologic Methods , Treatment Outcome
6.
Rev. bras. cir. cardiovasc ; 19(1): 29-33, jan.-mar. 2004. ilus, tab
Article in Portuguese | LILACS | ID: lil-363356

ABSTRACT

OBJETIVO: Avaliar a abordagem transeptal vertical ampliada em reoperações da valva mitral com átrio esquerdo pequeno. MÉTODO: De janeiro de 2001 a dezembro de 2002, 15 pacientes portadores de doença valvar mitral com indicação de reintervenção cirúrgica, átrio esquerdo pequeno (menor ou igual a 4,0 cm) e fibrilação atrial crônica, foram submetidos à abordagem transeptal vertical ampliada da valva mitral. Nove pacientes (pt) eram do sexo feminino. A idade variou de 22 a 48 anos. As indicações cirúrgicas foram: disfunção de prótese mitral (seis pt); insuficiência mitral (cinco pt) e dupla lesão mitral (quatro pt). Três pacientes apresentavam insuficiência aórtica associada e um pt, insuficiência tricúspide. Nove (60 por cento) pacientes encontravam-se em ICC CF III da NYHA e seis (40 por cento), em CF IV. RESULTADOS: A exposição do aparelho valvar mitral foi excelente. O tempo de circulação extracorpórea variou de 65 a 150 min (média = 95min). Foram implantadas próteses em todos os pacientes (15 mitrais, três aórticas e um tricúspide). A mortalidade hospitalar foi de 6,7 por cento, com um óbito devido a baixo débito cardíaco e falência de múltiplos órgãos. Um (6,7 por cento) paciente apresentou broncopneumonia na fase hospitalar. Dez pacientes permaneceram com fibrilação atrial, três pt reverteram para ritmo sinusal e um evoluiu com ritmo juncional. A permanência hospitalar média foi de 8,2 dias. Doze (85,7 por cento) pacientes encontram-se em CF I e dois (14,3 por cento) em CF II. A curva atuarial de sobrevida é de 92,5 por cento em 22 meses de seguimento. CONCLUSAO: A técnica cirúrgica empregada proporciona excelente visibilização do aparelho valvar mitral, com baixo índice de complicações.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Mitral Valve/surgery , Postoperative Period , Reoperation
7.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 15(3): 115-119, jul.-set. 2002. graf
Article in Portuguese | LILACS | ID: lil-362338

ABSTRACT

Os autores relatam o caso de um paciente com cardiopatia chagásica crônica e que, por apresentar fibrilação atrial, preenchidas as condições para a indicação, foi submetido a cardioversão elétrica, com vistas à restauração do ritmo sinusal. O objetivo foi alcançado, porém, ocorreu o aparecimento de doença do nó sinusal sintomática, o que motivou o implante de marcapasso cardíaco artificial endocavitário. Desenvolveu quadro clínico de endocardite infecciosa, sendo diagnosticada trombose gigante infectada no cabo-eletrodo. Foi submetido a cirurgia com circulação extracorpórea para exérese da mesma, tratado com antibióticos e com implante de marcapasso epimiocárdico. Desenvolveu nefrotoxicidade atribuída a um ou mais dos antibióticos, da qual se recuperou espontaneamente, com base em dados laboratoriais. Enfatizam os autores a necessidade de prudência na indicação de restauração do ritmo sinusal em casos de fibrilação atrial, principalmente quando a cardiopatia de base é a chagásica, na qual o comprometimento do nó sinusal é freqüente e, muitas vezes, inaparente.


Subject(s)
Humans , Male , Middle Aged , Chagas Disease/etiology , Atrial Fibrillation/therapy , Amiodarone , Aspirin , Midazolam , Pacemaker, Artificial , Sick Sinus Syndrome , Time Factors
8.
Rev. bras. cir. cardiovasc ; 17(3): 242-247, jul.-set. 2002. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-348584

ABSTRACT

MÉTODO: No período de agosto de 1997 a maio de 2001, 250 pacientes multiarteriais, consecutivos, foram submetidos à cirurgia de revascularização do miocárdio sem circulação extracorpórea. A faixa etária dos pacientes variou de 38 a 83 anos (média de 59,9 anos), dos quais 62 por cento eram do sexo masculino. A principal indicação cirúrgica foi a insuficiência coronariana crônica (82 por cento). Todos os pacientes foram operados por esternotomia mediana. RESULTADOS: Três (1,2 por cento) pacientes necessitaram de instalação de circulação extracorpórea. Nos demais 247 pacientes, realizou-se 592 anastomoses, com uma média de 2,4 pontes/paciente. A artéria torácica interna esquerda foi utilizada em 198 (80,1 por cento) pacientes, a artéria torácica interna direita em 5 (2 por cento) pacientes e a veia safena em 247 (100 por cento) pacientes. As artérias coronárias mais revascularizadas foram o ramo interventricular anterior (89 por cento) e o ramo marginal esquerdo (53 por cento). A mortalidade hospitalar global foi de 4 por cento, sendo a principal causa o infarto pós-operatório (1,2 por cento). Morbidade pós-operatória foi constatada em 23 (9,3 por cento) pacientes. O tempo médio de permanência hospitalar foi de 7,7 dias. CONCLUSÃO: Conclui-se da presente investigação, que a revascularização do miocárdio sem circulação extracorpórea em pacientes multiarteriais é factível, reprodutível e com baixo índice de complicações pós-operatórias


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Angina, Unstable/surgery , Coronary Disease/surgery , Myocardial Infarction/surgery , Myocardial Ischemia/surgery , Myocardial Revascularization/adverse effects , Myocardial Revascularization/methods , Angioplasty , Extracorporeal Circulation , Hospital Mortality , Postoperative Period , Time Factors
9.
Rev. bras. cir. cardiovasc ; 15(1): 32-8, jan.-mar. 2000.
Article in Portuguese | LILACS | ID: lil-255091

ABSTRACT

OBJETIVO: A maior complexidade técnica de implante é provavelmente o mais importante fator limitante do uso mais amplo das biopróteses aórticas "stentless". CASUÍSTICA E MÉTODOS: Quinze pacientes foram submetidos a troca valvar aórtica por bioprótese porcina "stentless", tipo Labcor, com técnica simplificada de implante - um plano de sutura com pontos separados ao nível do anel aórtico e suspensão dos pilares com sutura contínua. Doze pacientes eram do sexo masculino e 3 do feminino, com idade variando de 9 a 56 anos. As indicações cirúrgicas foram a estenose valvar aórtica em 8 (53,3 porcento) casos, a dupla lesão em 4 (26,7 porcento) e a insuficiência aórtica em 3 (20 porcento). Dez (66,7 pocento) pacientes apresentavam-se em classe funcional (CF) III da NYHA e 5 (33,3 porcento) em CF IV. RESULTADOS: Não ocorreram complicações na fase hospitalar. Em 2 (13,3 porcento) pacientes constatou-se, antes da alta hospitalar, presença de insuficiência central discreta da prótese, sem repercussão hemodinâmica. Um paciente apresentou endocardite bacteriana 14 meses após o implante, necessitando de reoperacão, evoluindo com choque séptico e óbito. A curva atuarial de sobrevida é de 93,3 porcento em seguimento médio de 23,5 meses, variando de 17 a 29 meses. Doze (85,7 porcento) pacientes apresentam-se em CF I (NYHA) e 2 (14,3 porcento) pacientes em CF II, sem a ocorrência de complicações tromboembólicas, escape paravalvular ou hemólise, no período avaliado. CONCLUSÃO: A técnica em questão é de fácil execução, reprodutível e com baixo índice de complicações, podendo constituir-se em mais uma opção nas operações de troca valvar aórtica


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Animals , Bioprosthesis , Aortic Valve Stenosis/surgery , Blood Vessel Prosthesis Implantation/methods , Postoperative Period , Suture Techniques , Swine
10.
Arq. bras. cardiol ; 44(2): 135-137, fev. 1985.
Article in Portuguese | LILACS | ID: lil-1216

ABSTRACT

Foram estudados 125 casos de crise hipertensiva, medicados com verapamil na dose de 5 a 10 mg por via venosa ou por infusäo gota a agota na dose de 25 mg durante 15 minutos. Todos os casos foram controlados através de monitorizaçäo da presäo arterial e freqüencia cardíaca e ECG nos tempos 0 (zero), 1,2,5,10,15,30,45 e60 minutos. Os resultados mostraram boa resposta anti-hipertensiva com iníco aos dois minutos e efeitos marcante entre 10 e 15 minutos, permanecendo até 60 minutos ou mais. Houve efeitos colaterais discretos de caráter transitório, sem repercussäo desfavorável


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Verapamil/therapeutic use , Hypertension/drug therapy , Verapamil/administration & dosage , Clinical Trials as Topic , Heart Rate/drug effects , Arterial Pressure/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL